Lifetime guaranted Image
TS IV SA
Advanced Bone Level Solution

TS IV SA

Advanced Bone Level Solution

The TS (Transcendent Solution) Implant System is one of the most widely used implants among dental professionals worldwide. Designed for optimal primary stability and enhanced osseointegration, this bone-level implant provides predictable outcomes in a wide range of clinical cases.

High Primary Stability & Easy Insertion
High Primary Stability & Easy Insertion

The self-tapping, dual-thread design and optimised body shape ensure secure, effortless placement.

Fair & Accessible
Fair & Accessible

One of the world’s most trusted implant systems — produced in state-of-the-art facilities with uncompromising quality control.

Fast Osseointegration
Fast Osseointegration

A portfolio of advanced implant surfaces — including SA and SOI — developed to support predictable performance in a variety of clinical situations.

Prosthetic Versatility
Prosthetic Versatility

Comprehensive prosthetic solutions for both aesthetic and functional restorations.

Excellent Long-Term Results
Excellent Long-Term Results

Platform switching helps preserve crestal bone and supports long-term success.

Broad Range of Indications
Broad Range of Indications

Available in multiple diameters and lengths for minimally invasive and versatile treatments.

TS IV SA

Self-Tapping & Dual-Thread Structure​

The self-tapping, dual-thread design of the TS Implant enables quick and precise placement while minimizing insertion torque. Its optimized macro and microstructure promote bone integration and long-term stability.

TS IV SA
Ø3.0 & Ø3.5
TS IV SA
Ø4.0 - Ø7.0
Only 2 Platforms for all Diameters

The TS Implant offers a user-friendly design with 2 platforms:

  • Mini: Implants with Ø3.0 mm and Ø3.5 mm
  • Regular: Implants with a diameter of 4.0 mm or more

A platform switch is possible between mini implants with mini abutments or between regular implants with regular abutments. Please note the corresponding color coding.

TS IV SA
TS IV SA
Trusted Stability. Superior Connection.

TS Implants combine an advanced corkscrew thread design, self-tapping ability, and dual thread for exceptional primary stability. With a precise Morse taper connection, the system ensures a secure fit between implant and abutment, eliminating micro gaps and helping protect against bacteria and bone loss.

TS IV SA
TS IV SA
Morse Taper Connection – Secure & Bacteria-Free​

The 11° morse taper connection ensures an exceptionally tight fit, preventing micro-movements and bacterial infiltration. Platform switching helps maintain soft and hard tissue stability, contributing to long-term implant success.

TS IV SA
TS IV SA

Design maximizing clinical convenience
  • Our Implants stand for maximized clinical performance, improved esthetics and high patient satisfaction
Surface Options
  • The Super Osseo Integration (SOI) surface offers a shortened healing time by over 35% relative to existing surfaces owing to improved osseointegration capability.

Specifications & Indications

III
(1.5º Tapered body)
ts-implants-3
  • A 1.5° tapered body advantageous for achieving primary stability.
  • Ideal for immediate and early loading.
  • Suitable for all bone types.

Torque: ≤ 40 Ncm

IV
(6º Tapered body)
Tes-implants-4
  • Designed with a more tapered body and wider thread pitch to achieve stronger primary stability while minimising compression at the surgical site
  • Achieves high initial stability even in soft bone
  • Ideal for soft bone and maxillary sinus procedures.

Torque: ≤ 40 Ncm

» For TS IV implants, reducing the speed to 15 RPM is recommended.

Color Coding of TS Implants

  • Our TS implants are available in a variety of diameters & lengths to optimally cover all indications
  • The outer packaging and labels provide valuable information about the enclosed product before opening: expiration date of sterilization, implant length & diameter, article & LOT number

Ø3.0 Ø3.5 |← Mini →| Ø4.0 Ø4.5 Ø5.0 Ø5.5 Ø6.0 Ø7.0 |← Regular →|
ts-dental

Recommended implant diameters

Suggested implant diameters based on tooth position serve as a general guide when bone volume and interdental space are sufficient. The final choice must always rely on the clinician’s professional judgement and the patient’s specific anatomical needs.

» For single-tooth replacements in the posterior region, implants with a diameter of 4.5 mm or greater are recommended.

Downloads pdf

 Surgical-Manual | TS Implant System
Surgical-Manual | TS Implant System
Manual / User Guide
PDF
2.38 MB
Surgical-Manual | Implant Placement Guide
Surgical-Manual | Implant Placement Guide
Manual / User Guide
PDF
3.35 MB
Surgical-Manual | Implant Selection Guide
Surgical-Manual | Implant Selection Guide
Manual / User Guide
PDF
1.59 MB
Flyer | TS Implant System
Flyer | TS Implant System
Flyer
PDF
609.5 KB

Take the next step with Osstem UK