OssBuilder
The Osstem OssBuilder is a high‑precision titanium membrane crafted for effective volume maintenance during bone regeneration. Its rigid, semi‑dome architecture accommodates alveolar defects without needing trimming or bending—streamlining GBR procedures while preventing soft‑tissue collapse.
Non-absorbable Titanium Membrane for predictable vertical and horizontal bone augmentation
The Osstem OssBuilder is a high‑precision titanium membrane crafted for effective volume maintenance during bone regeneration. Its rigid, semi‑dome architecture accommodates alveolar defects without needing trimming or bending—streamlining GBR procedures while preventing soft‑tissue collapse.
Why It Matters for Clinicians
Bone volume restoration poses surgical challenges—especially when aesthetics and graft stability are critical. The Osstem OssBuilder addresses this by delivering a pre-shaped, rigid membrane that simplifies implantation, supports multiple defect morphologies, and enhances healing predictability. For clinicians, this translates into streamlined GBR workflows, reduced risk of exposure, and more reliable outcomes in both functional and aesthetic cases.
Eliminates additional shaping steps—offering time‑saving convenience and wrinkle‑free placement.
Semi‑rigid dome shape prevents membrane collapse and preserves the graft’s volume during healing.
Available in OB2 (lateral defects) and OB3 (vertical/horizontal large defects) configurations—covering 1‑ to 3‑wall alveolar defects.
Microporous structure promotes blood flow and effective fluid diffusion, supporting bone formation.
Anchors, healing and cover caps support submerged or non‑submerged protocols while reducing risk of exposure.


3D Titanium Membrane for Predictable Bone Regeneration
- OssBuilder adapts to each patient’s soft tissue condition with either a Cover or Healing Cap
- Pre-formed 3D design ensures stability, prevents membrane exposure, and supports faster, safer bone regeneration
.webp)
.webp)
Design maximizing clinical convenience
- 3D Pre-formed Design requires no trimming or bending
- Line-up for various bone defect cases
.webp)
.webp)
Minimal exposure of membrane during bone healing
- Suturing with Cover Cap H: 0.3mm minimizes the possibility of exposure
- Healing Caps for non-submerged procedure for patients with insufficient soft tissues

.webp)
Minimal gingiva incision shortens recovery period
- High-rigidity curved mesh maintains its shape without fixation screws
- Secondary surgery can be performed with minimal incision
.webp)